Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chongqing Medicine ; (36): 3039-3042, 2017.
Article in Chinese | WPRIM | ID: wpr-608785

ABSTRACT

Objective To investigate the effect mechanism of sanguinarine on the proliferation,apoptosis,invasion and migration abilities of cervical cancer cells.Methods MTT,flow cytometer,cell scratch test and Transwell chamber assay were respectively used to detect the cellular proliferation,apoptosis,migration and invasion abilities after sanguinarine action.The expression levels of E-Cadherin,PTEN,β-catenin and MMP2 protein of cervical cancer cells after sanguinarine action were detected by Western blot.Results 0.6,0.8 μmol/L sanguinarine had the inhibitory effect on the proliferation of cervical cancer cells.After 0.8μmol/L sanguinarine action for 48 h,cervical cancer HeLa and Siha cells apoptosis rate were up to (45.68± 2.26)% and(31.89 ± 3.80)% respectively.0.8 μmol/L sanguinarine action for 3 h,cervical cancer cells HeLa and Siha adhesion rates were only (67.45 ± 2.13)%and(73.59± 2.61)%.0.8 mol/L sanguinarine action for 16 h,the invasion numbers of cervical cancer Hela and Siha cell were (39.64 ±1.98) and (43.87 ± 2.83) respectively.The expression amount of E-Cadherin and PTEN in cervical cancer cells after sanguinarine action was increased,while the expression amount of E-Cadherin and PTEN was weakened.Conclusion Sanguinarine has the proliferation inhibiting and apoptosis promoting effect on cervical cancer cells,its mechanism may be related to adhesion protein E-Cadherin,β-catenin and PTEN,MMP2.

2.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 56-60, 2015.
Article in Chinese | WPRIM | ID: wpr-637089

ABSTRACT

ObjectiveTo study the value of strain ratio from longitudinal section and cross section in differential diagnosis of benign and malignant thyroid nodules using ultrasonic elastography.MethodsA total of 118 patients with 153 thyroid nodules underwent examinations with real-time ultrasonic elastography to obtain the strain ratio from longitudinal section and cross section. Receiver operating characteristic (ROC) curves were used to evaluate the value of elastography. The nodules are divided into two groups, group one included nodules which were near the isthmus and group two included other nodules. Diagnostic results were compared with pathological results.ResultsThe area under the ROC curve (AUC) of the strain ratios for differentiating benign and malignant thyroid nodules were 0.906 and 0.844. There was no statistical difference (Z=1.542,P>0.05). The best diagnostic cut-off points of the strain ratios were 3.65 and 3.58. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value of the strain ratio from longitudinal section for differentiating benign and malignant thyroid nodules were 81.2%, 80.8%, 81.0%, 87.2% and 71.2% and those of strain ratio from cross section were 77.2%, 76.9%, 77.1%, 84.4% and 63.4%. In group one, the AUC were 0.903 and 0.830. There was no statistical difference (Z=1.125,P>0.05). The best diagnostic cut-off points were 3.30 and 3.28. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value of the strain ratio from longitudinal section for differentiating benign and malignant thyroid nodules were 86.2%, 68.8%, 80.0%, 83.3% and 73.3% and those of strain ratio from cross section were 78.6%, 58.8%, 71.1%, 75.9% and 62.5%. In group two, the AUC were 0.906 and 0.852. There was no statistical difference (Z=0.936,P>0.05). The best diagnostic cut-off points were 3.33 and 3.71. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value of the strain ratio from longitudinal section for differentiating benign and malignant thyroid nodules were 90.1%, 75.7%, 85.2%, 87.7% and 80.0% and those of strain ratio from cross section were 84.7%, 70.3%, 80.6%, 83.6% and 72.2%. ConclusionReal-time ultrasonic elastography is helpful to the differential diagnosis of thyroid nodules, but there is no statistical difference between the strain ratio from longitudinal section and cross section.

3.
Chinese Journal of Ultrasonography ; (12): 149-152, 2012.
Article in Chinese | WPRIM | ID: wpr-424756

ABSTRACT

ObjectiveTo study the clinical value of ultrasound elastography in evaluating the ablated zone and morphology of uterine leiomyoma and adenomyosis treated with percutaneous microwave ablation treatment(PMAT) under ultrasound guidance.MethodsEighteen patients were randomly chosen from 150 patients with symptoms uterine leiomyomas or adenomyosis who were treated with PMAT.Contrastenhanced Ultrasound(CEUS) and ultrasound elastography were performed before and immediately after PMAT.Compared with contrast enhanced MR were performed at 1 - 2 d after PMAT,the accuracy of ultrasound elastography and CEUS in evaluating the ablated range of PMA were analysed.Results Ultrasound elastography showed that the ablated zone was blue and the boundary with the surrounding tissues was clear.The ablated zone showed no enhancement with CEUS and enhanced MR.The mean diameter of the ablated zone in ultrasound elastography,CEUS,and contrast enhanced MR was (4.90 ±1.12)cm,(4.64 ± 0.93) cm,and (4.89 ± 1.02) cm,respectively.The diameter in ultrasound elastography was slightly larger than that in CEUS ( P =0.02) and had no statistical difference with that in contrast enhanced MR ( P =0.44).ConclusionsUltrasound elastography can accurately show the coagulation range immediately after PMAT and is supposed to be a method to evaluate the ablated zone noninvasively immediately after PMAT.

4.
Medical Journal of Chinese People's Liberation Army ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-557424

ABSTRACT

Objective To study the side-effects of immunosuppressant cyclosporine A (CsA) on the circulatory system of rabbit and the mechanism of its toxicity. Methods Eighteen male New Zealand white rabbits were randomly divided into three groups. CsA were administered intravenously in 5mg?kg~ -1?d~ -1 to group A and in 15mg?kg~ -1?d~ -1 to group B for consecutively 21 days, meanwhile, as a control, an equal amount of saline was given to group C. Ultrasound and physiometry instrument were used to assess the experimental results. Results No changes were found in the dimension of any cardiac chamber in both groups A and B, obvious thickening occurred in the interventricular septum and the posterior wall of the left ventricular, pericardial effusion appeared and the weight of cardiac muscle increased significantly, and the diastolic and systolic blood pressure in ascending aorta decreased in groups A and B compared to group C. Also, the systolic pressure in left ventricular decreased while the diastolic pressure increased significantly in groups A and B. Conclusion Large dose of CsA has strong toxic effects on cardiac muscles, and can cause cardiac malfunction.

5.
Medical Journal of Chinese People's Liberation Army ; (12)1981.
Article in Chinese | WPRIM | ID: wpr-553800

ABSTRACT

Objective To discuss the ultrasonographic features of immunosuppressants induced hepatotoxicosis after renal allograft. Methods The pre operative and postoperative ultrasonographic features of liver and gallbladder (GB) of 29 renal transplantation patients with clinical hepatotoxicity, after the use of CsA as the main immunosuppressive agent, were evaluated. Results Out of the 29 patients, 23 exhibited enhanced liver echo and 6 patients had features of fatty liver. The thickness of gallbladder wall was around 0.3cm in 21 patients. The morbidity rate of hepatotoxicity was 69% (20/29) in three months. Conclusion The main ultrasonographic features of immunosuppresive agent induced hepatotoxicity were enhanced liver echo, thickened gallbladder wall and unclear echo from GB. These findings provided important subsidiary diagnostic signs for hepatotoxicosis, especially three months after renal allograft. At this time, not only the allograft renal should be examined, but also the liver and gallbladder should be scrutinized with ultrasound. The ultrasonographic changes together with the clinical laboratory data could serve as a guidance for the administration of immunosuppressive drugs.

SELECTION OF CITATIONS
SEARCH DETAIL